Categories: Framing

Large Girder Trusses

Using Girder Trusses for Open Framing

Today I want to quickly share some photos from a commercial building that we’re in the process of constructing this winter. We’re building a major addition for a Chrysler Dealership in Claremont, NH – Lambert Auto Sales. The project involves adding a large new showroom to an existing older building while maintaining some tight property set-backs. In order to accomplish that the architect had to “span” over a corner of the old building with the new.

Needless to say that resulted in some advanced framing and engineering. The original plan actually had a couple columns in the middle of the new showroom in order to support the old roof framing along with the new. I came up with a plan to remove all those columns and span the new showroom with a large girder truss. Basically a girder truss is usually a larger, stronger truss that acts as a beam or girder. The girder truss is then used to support other trusses and/or roof framing members.

Longer Spans with Engineered Lumber

Today it’s possible to span further and hold larger loads with trusses built using engineered lumber. The large girder truss shown in these photos is built with a combination of dimensional lumber and TimberStrand® engineered lumber. This particular truss spans 48 feet and has an average depth of almost 9 feet. It weighs almost 5,000 lbs and will support the new roof (span of 32 feet) and a portion of the existing roof.

The Sky’s The Limit

While you may never need a truss of this size you should be aware of how easy it is to support long spans and large loads with wood framing like this. Truss design and manufacturing have advanced to allow for some really exciting building designs. If you want to eliminate columns, open up large spaces and work with wood products than you’re in luck!

Speak with your local truss manufacturer, architect or engineer for help in designing and building structures like this. You will be very surprised at the few limitations that exist.

Todd Fratzel

I'm full time builder for a large construction company in New Hampshire. I run their design-build division that specializes in custom homes, commercial design-build projects and sub-divisions. I'm also a licensed civil and structural engineer with extensive experience in civil and structural design and home construction. My hope is that I can share my experience in the home construction, home improvement and home renovation profession with other builders and home owners. I'm also the Editor-in-Chief and Founder of Tool Box Buzz. Please feel free to contact me if you have any questions, suggestions or you'd like to inquire about advertising on this site.

View Comments

  • Todd, very cool indeed. Curious as to how far apart these can be placed from each other? My uneducated guess is 5 feet. Does it depend on what you put on top of them?

    • Fred - Typically these are used as a single "girder" as in this situation. This one will support smaller trusses that rest on top of it. I'll post more pictures as the remaining roof goes up so that it makes more sense.

  • Those girders are just what I'm looking for. I'm trying to span between columns that are 36 ft. apart and carry a roof load of 225 plf. Problem may be that they can't be deeper than 24". Should I go to steel?

Share
Published by
Todd Fratzel

Recent Posts

Framing Stick Nailer vs Coil Nailer

Which is Better a Stick Nailer or Coil Nailer? Framers have many choices in nailers…

12 months ago

How Many Roofing Nails Per Square of Shingles

Estimating How Many Nails for a New Roof When it comes to estimating materials for…

1 year ago

Composite / PVC Decking – Layout Tips & Advice

Composite / PVC Decking Layout Tips and Advice Composite and PVC decking have really changed…

1 year ago

Benefits of an ERV System (Energy Recovery Ventilator)

Benefits of ERV Systems (Energy Recovery Ventilator) If you're building a new home or doing…

2 years ago

Vermiculite Attic Insulation Abatement

Vermiculite Attic Insulation If your home was built before 1990 there is a chance it…

2 years ago

Nuisance Tripping of AFCI (Arc Fault) Circuit Breakers

Arc Fault (AFCI) Circuit Breakers Tripping Often An arc-fault circuit interrupter (AFCI) or arc-fault detection…

3 years ago