As you can see from the photo we’ve installed the fireplace early in the construction process. By installing the fireplace early on we can properly install it and make certain that all clearances are maintained as we build the house around the fireplace. Typically these type of fireplaces require some minimum distance between combustible materials. In this case we need to maintain a minimum of 2 inches between the fireplace components and any combustible materials.
This fireplace features two options that make this a great way to supplement your heat. First of all the unit comes with a dedicated fresh air intake. You can see the fresh air intake duct on the left side of the fireplace. It’s really important to use outside combustion air in order for the fireplace to work properly. Outside air helps prevent effects from negative air pressure. This fireplace also features a circulating fan to help push warm air from the firebox out into the room. These type of fans really make fireplaces very effective in heating large spaces. This fireplace is located in a large family room that’s open to the dining room and kitchen.
Probably the most important part of any wood burning fireplace is the chimney. The chimney has so many different requirements that I’ll leave some of it for another day. For this house we’ll be building a chimney chase on the roof (the chase will be sided to match the house). Inside the chimney chase will be a UL approved Stainless Steel Class “A” Insulated Chimney pipe. Most fires cause by wood burning fireplaces originate in faulty chimneys. I HIGHLY recommend you hire a certified, reputable company to install your chimney.
I’ll write another post when we finish the chimney chase so you can see the finished product.
Which is Better a Stick Nailer or Coil Nailer? Framers have many choices in nailers…
Estimating How Many Nails for a New Roof When it comes to estimating materials for…
Composite / PVC Decking Layout Tips and Advice Composite and PVC decking have really changed…
Benefits of ERV Systems (Energy Recovery Ventilator) If you're building a new home or doing…
Vermiculite Attic Insulation If your home was built before 1990 there is a chance it…
Arc Fault (AFCI) Circuit Breakers Tripping Often An arc-fault circuit interrupter (AFCI) or arc-fault detection…
View Comments
Can you install a heatilator into a fireplace that is already built? The house was built in 1980's.
Thank you for your time,
Kelly
@ Kelly - Very interesting question. I've never seen it done but that's not to say it can't be. I think the trick would be finding a heatilator that will fit inside the existing fireplace and meet the manufacturer's specifications for clearances. You could start by creating a drawing of the opening you have an searching for a fireplace that would fit the space. Chances are you'd have some modifications needed to make it all fit and look right.
I have a heatilator woodburning fireplace in a home we just bought.
The box is lined with firebrick; metal backing behind it. I noticed that there is a space, approx. 1/2 inch, on each side of the back portion of the brick. This back wall/portion also moves slightly when I touch it (for cleaning). Is this normal/safe? Also, the flue is a double wall pipe with stainless for the inner pipe. Any thoughts on this type of installation?
We plan to use the Heatilator to burn wood this winter. Your thoughts on safety, given the above.
Thanks, P. Prewitt.
@ Prewitt - I'm really not sure about that space and I recommend you check with the dealer/manufacturer just to be sure. Double lined flue pipes are the standard now and required by law in most places. Best of luck and I hope you enjoy your new Heatilator
I have a Heatilator E36 woodburning fireplace and would like to have something more efficient installed. The manual and on the fireplace says that unvented logs are not allowed (has not been tested for use in this firebox). Vented logs would not be efficient or produce much heat. I have access to propane gas. Do you know of a gas insert that would work in this unit? What would have to be done to the piping in the chimney as well?